Test Results
TYPICAL RESULTS FOR DURASTILL MODELS
| TEST SUBJECT |
AMOUNT SPIKED /mg/l |
EPA LIMIT |
TIMES EPA LIMIT SPIKED |
RESULT mg/l |
% REMOVED |
| NITRATE |
19.3
| 10
| 1.93 |
<0.01 |
>99.0 |
| CHLORIDE |
303 |
180.8 |
.60 |
<0.2> |
>99.7 |
| CHLORINE |
50 |
N/A |
N/A |
2.8 |
>94.4 |
| FLUORIDE |
2.08 |
N/A |
N/A |
0.05 |
>97.6 |
| COLIFORM /100ml |
1200 |
0.0 |
1200 |
0.0 |
>99.9 |
- Briggs Engineering & Testing Co. Inc.
TEST RESULTS PERFORMED ON TYPICAL DURASTILL MODELS
| TEST SUBJECT |
AMOUNT SPIKED /PPM |
EPA LIMIT /PPM |
TIMES EPA LIMIT SPIKED |
RESULT /PPM |
% REMOVED |
| SILVER |
4.0 |
0.05 |
80 |
<0.024 |
>99.4 |
| ARSENIC |
4.0 |
0.05 |
80 |
<0.006 |
>99.8 |
| CADMIUM |
4.0 |
0.01 |
400 |
<0.01 |
>99.5 |
| LEAD |
4.0 |
0.05 |
80 |
<0.05 |
>98.7 |
| SELENIUM |
4.0 |
0.01 |
400 |
<0.01 |
>99.7 |
RESULTS USING POST FILTER WITH TYPICAL DURASTILL MODELS
| TEST SUBJECT |
AMOUNT SPIKED /PPM |
EPA LIMIT /PPM |
TIMES EPA LIMIT SPIKED |
RESULT /PPM |
% REMOVED |
| LINDANE |
0.531 |
0.004 |
132 |
<0.0002 |
>99.6 |
| ENDRINE |
0.155 |
0.0002 |
775 |
<0.0002 |
>99.8 |
| METHOXYCHLOR |
0.530 |
0.100 |
5.3 |
<0.002 |
>99.6 |
| THM |
66.7 |
0.10 |
667 |
<0.1 |
>99.2 |
| BENZENE |
0.50 |
N/A |
N/A |
<0.015 |
>97.0 |
| TCE |
1.0 |
N/A |
N/A |
<0.043 |
>95.7 |
< = less than (below detectible limit stated)
> = greater than
* = standards vary according to average maximum daily air temperature
mg/l = milligrams per liter
ppm = parts per million
N/A = no EPA standards available
% removed are shown as worse case for line entry
KSTL - Kansas City Testing Labs - Kansas City, MO

[BACK TO HOME PAGE]
Durastill Export, Inc.
86 Reservoir Park Drive
Rockland, MA 02370
TEL: (781) 878-5577 FAX: (781) 878-2224
E-mail: sales@durastill.com
© 2001 Durastill Export, Inc. All rights reserved.